Along with the
increased data collection capabilities of a modern automation
system comes the need to provide timely and meaningful reports
of the data. Kruse Controls, Inc. can provide scheduled
or event triggered reports in printed or email formats.

Project Examples
Control System for
aluminum web anodizing
line with database
server interface

SUMMARY:
The anodizing line uses a programmable logic controller (PLC)
and a human machine interface workstation (HMI) for process control.
A Microsoft SQL Server database was used for production setup and
process information storage.

Control system for three aluminum web coating
lines with common
database server

SUMMARY:
The anodizing line uses a programmable logic controller (PLC) and a human
machine interface workstation (HMI) for process control. A Microsoft SQL Server
database was used for production setup and process information storage.

Downtime Collection
and Reporting System for Juice Line

SUMMARY:
Developed HMI and Visual Basic front end to create real-time
networked display of Juice Line status as well as automatically
collect actual downtime reasons with time stamp.

Custom
alarm
analysis system for human machine interface (HMI) software package

SUMMARY:
Developed a Microsoft VisualBasic application to allow a user to query process
alarm information inserted into a Microsoft SQL Server database from an off the
shelf HMI software package and generate historical analysis reports.

Automation of
production ticket generation and
Tracking for a vending machine
manufacturer with an Interface to their ERP System

SUMMARY:
Developed a Microsoft Visual Basic application to automatically generate
barcoded production tickets from daily production schedules. Developed a Visual
Basic application to update the ERP records by receiving scanned barcode
information upon completion of the vending machine manufacture and quality test.

Development of an
OPC
I/O Server for Communication of a
human machine interface (HMI) to a
programmable logic controller (PLC)

SUMMARY:
Used Microsoft Visual C++ to develop an OPC I/O server for communication between
an HMI and a PLC.

Pipeline Pigging and
Leak Detection

SUMMARY:
Pigging Operation for a 10-mile pipeline carrying No.6 Fuel Oil
from the terminal to a Power Plant using PLC’s and Dial-up Modems.
Reports are generated using MS SQL server and Visual Basic data
report designer.

Pipeline Leak
Detection and SCADA System

SUMMARY:
Leak detection and data acquisition for a 6 mile Jet fuel
pipeline using PLC’s and Dial-up modem. Reports are generated using
MS SQL server and Visual Basic data report designer.
|